Comparison of different segmentation approaches without using gold standard. Application to the estimation of the left ventricle ejection fraction from cardiac cine MRI sequences. - Université Clermont Auvergne Accéder directement au contenu
Communication Dans Un Congrès Année : 2011

Comparison of different segmentation approaches without using gold standard. Application to the estimation of the left ventricle ejection fraction from cardiac cine MRI sequences.

Jessica Lebenberg
Jean Cousty
Muriel Lefort
Elodie Roullot
  • Fonction : Auteur
Laurent Sarry

Résumé

A statistical method is proposed to compare several estimates of a relevant clinical parameter when no gold standard is available. The method is illustrated by considering the left ventricle ejection fraction derived from cardiac magnetic resonance images and computed using seven approaches with different degrees of automation. The proposed method did not use any a priori regarding with the reliability of each method and its degree of automation. The results showed that the most accurate estimates of the ejection fraction were obtained using manual segmentations, followed by the semiautomatic methods, while the methods with the least user input yielded the least accurate ejection fraction estimates. These results were consistent with the expected performance of the estimation methods, suggesting that the proposed statistical approach might be helpful to assess the performance of estimation methods on clinical data for which no gold standard is available.
Fichier principal
Vignette du fichier
Comparison_of_different_segmentation.pdf (336.81 Ko) Télécharger le fichier
inserm-00773261_edited.pdf (354.67 Ko) Télécharger le fichier
Origine : Fichiers produits par l'(les) auteur(s)
Origine : Fichiers produits par l'(les) auteur(s)
Loading...

Dates et versions

inserm-00773261 , version 1 (12-01-2013)

Identifiants

Citer

Jessica Lebenberg, Irène Buvat, Mireille Garreau, Christopher Casta, Constantin Constantinidès, et al.. Comparison of different segmentation approaches without using gold standard. Application to the estimation of the left ventricle ejection fraction from cardiac cine MRI sequences.. Annual International Conference of the IEEE Engineering in Medicine and Biology Society., Aug 2011, Boston, United States. pp.2663-6, ⟨10.1109/IEMBS.2011.6090732⟩. ⟨inserm-00773261⟩
726 Consultations